Instruction manual of EZM Programmable Counter consists of two main . EMKO Elektronik warrants that the equipment delivered is free from defects in. BUT it’s a negative number and I cannot figure out what to do? HELP PLEASE? EMKO ESM Temperature Controller-img_jpg. ESM, ESM, ESM, ESM, ESM ESM 8 mm. Green 4 EMKO Elektronik warrants that the equipment delivered is free from.

Author: Vudohn Mazugor
Country: Pacific Islands
Language: English (Spanish)
Genre: Science
Published (Last): 27 February 2008
Pages: 245
PDF File Size: 8.15 Mb
ePub File Size: 10.58 Mb
ISBN: 486-5-46363-702-1
Downloads: 5386
Price: Free* [*Free Regsitration Required]
Uploader: Shakagar

Siampower Technology Co.,Ltd.

I am technically challenged but could tell me how to test the thermocouple exactly? I own toper cafemino. If you have a electronic multimeter it may have an input for thermocouples. Your thermocouple is likely disconnected or has a broken wire.

I would assume the bottom value that you are setting is the maximum temperature it will reach before cutting off the gas valve fire safety feature. When you said ” check is to see if the thermocouple type is set properly in the controller” Thanks for your help!

Some temp controllers indicate a bad or disconnected thermocouple differently. Hello Fellow Roasters, we just received our Toper 15 kilo roaster from Turkey and could not be more excited to start roasting.

  DISOCIACION ELECTROMECANICA PDF

Hi dear I just read your post about toper drum tempreture. You may fix it for sure. All times are GMT The time now is One you know what type you have you need to es-m4430 into the controllers settings to see if it’s setup for that type of thermocouple.

I use different thin thermocuple connected with Phidget So first thing you need to do is check the type of thermocouple you have If you take a look at the attached picture If you can may not be possible you could unplug the thermocouple from the controller and plug into the handheld device.

Yes the bottom value is setting the maximum temp it will reach before the gas gets cut off.

Emko Elektronik

I have the pre-set temp at but the top number should read the current temp of the drum How do I check this? In my scenario I could route my cabling to this device when I was having issues Charlie If you are afraid of failure or losing money, quit while you are ahead. But after using toper i discover they use J type thermocouple and honestly its very thick and gave low value for tempreture. Steve Green Ems-4430 City Roasters.

  BRIKWARS 2010 PDF

It’s odd that its showing negative Results 1 to 9 of 9. Brand new then contact Toper. Obviously be careful you turn on your drum and its cold You can test a thermocouple with a multimeter, it should read a few ohms, I emjo suggest a disconnected probe or bad connection at the controller?

Its the wiring problem you have to opposite the wire in behind the temperature controller.

Originally Posted by fivestarcoffeeroasters. BUT it’s a negative number and I cannot figure out what to do? The one in my older toper flashes the display at loss of continuity, the phidget shows a negative number. I would hope that the manufacturer would tell you this.

EMKO ESM Temperature Controller

Esm-44430 you reach the thermocouple inside of the drum? Second thing I would check is to see if the thermocouple type is set properly in the controller.

They have excellent customer service. Can you shoot me a link or something to a hand held device I could purchase to use?